Input devices for local box installation
LM-SxED
Article number: 22185326
EAN number: 9006210436876
Login to view your exclusive prices and stock availability
No account yet? Register and upgrade to access your individual pricing and stock info.
Typically available in stock
Technical Data
Electrical Properties
Safety Class
SC2
Emergency included
No
Lum Data
No
Light Distribution
Light Distribution
STD - standard
Physical Characteristics
Dimensions
48x28x15 mm
Length
48 mm
Width
28 mm
Height
15 mm
Weight
0.026 kg
Colour
White
Degree of protection
IP20
overviewFeatures_indoor
Degree of protection
IP20
Norms and Standards
Certificates




Drawings
Dimensional sketch
Downloads
Input devices for local box installation
22185326 LM-SxED
Input module with four addressable inputs for integrating a conventional light/window/blinds/screen momentary-action switch, switching/changeover switch/momentary-action switch, motion detector, time switch or other contact-maker in a bus-controlled lighting and room management system.
Depending on the addressing of an input, users can operate all the actuators in a room, or one actuator group in the room.
Can be used as:
• Switching input: short press on one of the connected momentary-action switches toggles between the two scenes "Absent 0" and "Present 1"
• Switching-dimming input: short press on a connected momentary-action switch toggles between the two scenes "Absent 0" and "Present 1". Long press on the switch: the lighting is dimmed alternately up and down.
• Switching-changeover input: closing a contact-maker connected to the "T1 / T2" inputs runs the "Present 1" scene, while opening a contact-maker connected to the "T3 / T4" inputs runs the "Absent 0" scene. Connect a continuous contact-maker to the linked "ON" and "OFF" terminals. Each module input has two terminals: "ON" and "OFF".
• Blinds and screen input: blinds/screens in the room can be raised by pressing a momentary-action switch connected to the "T1/T2" inputs, and lowered by pressing a momentary-action switch connected to the "T<" inputs. Press and hold (> 3s): blinds/screens move into the limit of travel or working position. Each module has two "T>" and "T<" inputs.
• Window input: windows in the room can be opened by pressing a momentary-action switch connected to the "T>" inputs, and closed by pressing a momentary-action switch connected to the "T<" inputs. Press and hold (> 3s): window moves into limit of travel. Each module has two "T>" and "T<" inputs.
Power supplied via bus line; bus lines can be screw-connected to the input of the module. Installed in flush socket (Ø 60 mm, depth 42 mm) fitted behind switch and made of halogen-free flame-retardant polycarbonate, transparent. The contact-makers must have an isolated switching contact designed for at least 15VDC and must be suitable for connecting to the input lines of the module. Dimensions 41.2 x 28.2 mm, weight: 12 g